Ask Community about Master Spas
Replacement for the X310320 topside control panel
Since the topside control panel X310320 has been discontinued, and mine isn't working, what do I replace it with? I've looked a bit online, and can't find an answer.
I am looking for replacement filters for a 2005 Down Ends hot tub
I am looking for replacement filters for a 2005 Down Ends hot tub. Serial number M508164. Please send me price and numbers on filters.
hello i have a master spa lsx 700 want to program to not run from 5 to 8 pm in order to get around P...
hello i have a master spa lsx 700 want to program to not run from 5 to 8 pm in order to get around PGE electrical load sur charge on energy bill. any advise ... can i do it with filter program some how .?
I have Twilight 6
I have Twilight 6.2 and this morning the control panel won't respond to any action. It was replaced 2 years under warranty but now there is no warranty left.
I need to find the part number (I think it might be X310220 which might no longer be made?) but where do I confirm that?
Where can I buy the part for this? is the length of time for these panels really only 2 years?
In our H2X Trainer, should water in the spa end be circulating continuously during the 4hr filtratio...
In our H2X Trainer, should water in the spa end be circulating continuously during the 4hr filtration cycle? Or does it cycle on and off during the 4hr period?
I have a 2019 Twilight 7
I have a 2019 Twilight 7.2 and my touch control is dark. There are no signs of moisture and checking my 3 fuses shows that they are ok.
My pool pump went out 2 weeks ago and the pool equipment and spa share the same sub panel.
Are there tech instructions on how to install a new control panel? Is the x310334 a direct replacement for the x310220?
Bonjour mon module de commande master Spa - X310220 est HS et n’est plus commercialisé
Bonjour mon module de commande master Spa - X310220 est HS et n’est plus commercialisé. Lequel acheter et comment le remplacer
Good afternoon - The topside controller is blank on my Twilight TS240
Good afternoon - The topside controller is blank on my Twilight TS240. I've powered down the spa twice in order to reset to no avail.
The filtration cycle was still running this morning and maintained its heat overnight. Before it went blank, I noticed there was some condensation on the inside of the screen, and had been that way for a while. Is there a way to test the controller to make sure it is the problem? I believe the original controller is PN x310220 or x310223 both of which seemed to be discontinued.
Looks like they are now calling for x310334? Thanks, Vern
2019 Twilight 8.2 ozonator question
I did some maintenance on my tub this year and change the UV light and quartz tube on the ozinator. I also tested the check valve and the injector to see if they were plugged or gunked up.
Neither seemed to be the case. My question is whether I should be seeing bubbles coming out of the small hole leading from the side of the injector into the tub? I actually don't ever remember seeing bubbles, but now I'm wondering if that is correct.
There is a strong flow coming from that smaller hole and a very strong flow coming from the main circulation pump outlet into the tub 24/7. Should there be bubbles anywhere?
How do I get rid of the sandy feeling on the inside of the hot tub?
I emptied and cleaned my hot tub, filled it up and put chemicals in it. When i got in it later, the inside area feels like sand particals around the whole inside.
I'm thinking I put too much of some granual chemical in? It has always been really clean and nice when I've emptied and cleaned it before.
I don't know what I'm doing wrong. I use the test strips to check the levels of chemicals.
Pumps not turning on.
I've replaced the #1 pump and refilled the spa, after turning it on and waiting trough the Priming stage the pumps will not turn on. leaving the jet buttons on or off, I've tried priming the pumps by loosing the discharge fittings thinking it was airlocked, still no results. Please call or email, Thank you
Cross trainer 2008 Jet # 1 won't shut off
Jet #1 will not shut off.Press the button once it goes high speed, press again goes back to low speed.Temperature is good, filter cycle is set at 6 hours, Was set for standard operation I changed it to sleep(slp) mode but no change, pump continues to run.
Hello, i have a to 7.2 without the circ. Pump. Can I add one after?
What is this part on my twilight series hot tub?
There is a piece of PVC, maybe 1/2 inch diameter, that is open ended with what appears to be a rubber check valve. It is inside the cabinet.
It’s behind the right panel of the tub if you are looking at the pumps. There is also a soft tubing nearby, probably the same diameter. When the pumps come on water sprays out of the PVC “check valve”. Nothing comes out while normally circulating, just when jets are started.
This part does not show up in any manual or parts list.
I’m pretty sure I need one. Can I plug it short term until I find a new one?
I was told that Master Spas isnt building spas with the circulation pump
Were interested in a twilight 8.25 but being told to stream line the manufacturers process they took them off. What are the pros and cons of having a circulation pump and can they be added later?
We THINK wed prefer one but just cause thats what we were told. Please advise
What is standard delivery?
Does that mean they deliver and install. All we have to do is have the electrician set up the right power source.
Filter placement
I have a Twilight 7.2 Series Spa I took the filters out the first time not sure what is the proper spot for each filter to back in? Does it matter if one is in the right side or the left side??
model and info needed
Hi we have an older Freedom Spa Master Spa it's blue in color and it's seats 6 and it has a corner filter pma 40 I have no idea what model it is because of the fact the tag on it on the outside is unreadable due to its age, the spa is fantastic! Love the Spa we love it but I just cannot find out any other info on it and the filter tag is gone so if you could help me that would be great.
I can tell you it's darker blue has founder on one side where feet jets meet milter opening. It seats six. Has brown outer shell.
The control button panel says freedom and has one light and two buttons and temp button four in total. It has two jet control turn knob's on the sides one by the neck massage seat and one on the lumbar side outer ledge.
Leak?
I did not check on my hot tub for about two weeks due to illness. When a checked a few minutes ago there was very little water in the spa.
It is raining so I can’t tell where it is leaking. It is a Twilight Series and it’s about six months old and I have had no problems with it up to this point. I have turned the power off but we may have freezing temps tonight.
What should I do? Sent from my iPhone
TS 7.2 2012
Hello Hope you can help I own a Master Spa Twilight Series 7.2 2012 and I need a new air control DSG 6-Spoke Waterfall Diverter Assembly. The problem I have is that I live in the UK . Could you please advise who is Master Spa retailer for spare parts in the UK Kind Regards Gary
Need Advice from Real Consumers?
Ask consumers like you for honest recommendations and tips, or share your own experience to help others.
Your question will appear on the site once it is reviewed by our moderation team. While you wait, feel free to browse other community discussions.
Top Contributors

X310320 was used in many Twilight Series Master Spas in 2022 and 2023. You can replace this currently with X310342 which is a Trapezoid shape or X310341 which is a Watch/diamond shape. There is a sticker overlay that can be found with part X509138 (watch) or X509124 (trapezoid). You can always call the factory at 1-800-860-7727 with your spa serial number to ask about the most current part numbers.